Cement
Cement is the binder used to create concrete and mortar. The manufacturing of cement requires stringent control and a number of tests being performed in cement plant laboratories to ensure that the cement is of the desired quality and that it conforms to the requirements of the relevant standards.
The most important use of cement is the production of concrete and mortar, which are the combination of cement and an aggregate to form a strong building material that is durable in the face of normal environmental effects.
High Pressure Cement Autoclave
Product code
UTCM-0020 |
High Pressure Cement Autoclave, 230 V 50-60 Hz, 1ph |
Standarts
ASTM C151, C490; UNE 7207
The UTCM-0020 High Pressure Cement Autoclave is designed to perform expansion tests on cement specimens.10 specimens can simultaneously be tested in the high pressure steam vessel of 154 mm diameter and 430 mm height.
The Autoclave consists of a pressure gauge, pressure regulator, temperature regülatör, control switches safety valve and specimen rack. Certified conforming to INAIL procedure.
UTCM-0033A Two Gang Shrinkage mould and Length Comparators (UTCM-0200 or UTCM-0210) should be ordered separately.
The High Pressure Cement Autoclave is supplied complete with;
- Specimen Rack, 10 samples capacity
Dimensions |
450x475x1080 mm |
---|---|
Weight (approx.) |
55 kg |
Power |
2600 W |
Blaine Air Permeability Apparatus
Product code
UTCM-0240 |
Blaine Air Permeability Apparatus |
UTCM-0241 |
U Manometer Tube |
UTCM-0242 |
Manometer Liquid 250 ml |
UTCM-0243 |
Cell with Perforated Disc and Plunger |
UTCM-0244 |
Filter Paper 100 pcs. |
UTCM-0245 |
Filter Paper 1000 pcs. |
UTCM-0246 |
Reference Cement 5 g, ASTM |
UTCM- 0282 |
Reference Calibration Sand – Fine, Approx. 100g |
UTCM- 0284 |
Reference Calibration Sand – Coarse, Approx. 100g |
Information
EN 196-6; ASTM C204; AASHTO T153
The UTCM-0240 Blaine Air Permeability Apparatus is used to determine the fineness of Portland cement, limes and similar powders expressed in terms of their specific surface.
UTCM-0246 Reference cement, UTCM-0282 and UTCM-0284 reference calibration sands should be ordered separately.
The Blaine Air Permeability Apparatus is supplied complete with;
- U Manometer Tube
- Manometer Liquid, 250 ml
- Test Stand
- Rubber Aspirator
- Cell with Perforated Disc and Plunger (with UTEST Certıfıcate of Cell And Plunger Dimensions for Calculation of Cell Specimen Volume)
- Plastic Funnel
- Filter Paper, 100 pcs.
|
UTCM-0282 |
UTCM-0284 |
---|---|---|
Specific surface (aporox. cm2/g) |
3890 |
2980 |
Density (aporox. 2,65 g/cm3) |
2,65 |
2,65 |
Porosity (aporox.) |
0,50 |
0,50 |
Dimensions |
300x540x210 mm (packed) |
---|---|
Weight (approx.) |
7 kg (packed) |
Heat of Hydration Calorimeter with High Resolution D. Th.
Product code
UTCM-0347 |
Heat of Hydration Calorimeter with High Resolution Digital Thermometer, 230 V, 50-60 Hz, 1 ph |
Information
EN 196-8; ASTM C186
When Portland or hydraulic cement is mixed with water, heat is generated as a result of the exothermic reaction. The heat generated by cement’s hydration raises the temperature of concrete and this temperature rise causes expansion while concrete is hardening, especially under conditions when heat can not be readily released.
The UTCM-0347 Heat of Hydration Calorimeter is used for determining the heat of hydration of low heat Portland and hydraulic cement. The apparatus consists of a Dewar flask housed in an insulated box, an electric stirrer, a filler funnel and a high resolution battery operated electronic thermometer.
Features
- Displays, saves and prints ΔT, Min., Max. and Mean Values
- Audible alarm if limit values are exceeded
- Resolution 0.001°C
- PT100 Probe Measuring Range -40 to +300°C
- Protection class IP65
- Accuracy 0.05°C
- Memory 10.000
- Complete with resolution test certificate
- Supplied complete with MS EXCEL template for data processing
Dimensions |
300x200x650 mm |
---|---|
Weight (approx.) |
13 kg |
Muffle Furnace
Product code
UTD-1462 |
Muffle Furnace 6 lt. 1200°C Max. Temperature with Programmable Timer, 20-240 V 50-60 Hz |
Information
EN 196-2; ASTM C25, C115
UTD-1462 Muffle Furnace is used for determining the loss on ignition and insoluble residue of cement and building lime.
Working temprature and time can be programmed with PID digital control system.
Digital Thermometer Features
Temperature Controller |
PC 442/2 |
---|---|
Max. Temperature |
1200 °C |
Max. Continuous Temperature |
1150 °C |
Temperature Deviation at Set Point |
± 2°C |
Heat Up Time to Max. Temperature |
50. min |
Internal Volume |
6 L |
Phase |
1 |
Internal Dimension |
140x180x200 mm |
---|---|
External Dimension |
650x550x580 mm |
Weight (approx.) |
56 kg |
Power |
2000 W |
Vicat Test Sets
Product code
UTCM-0451 |
Vicat Apparatus |
UTCM-0452E |
Vicat Mould EN Base ID 80 mm, Top ID 70 mm, Height 40 mm |
UTCM-0452A |
Vicat Mould ASTM Base ID 70 mm, Top ID 60 mm, Height 40 mm |
UTCM-0453E |
Initial Vicat Needle EN 1.13 mm dia. |
UTCM-0453A |
Vicat Needle ASTM 1 mm dia. |
UTCM-0454E |
Final Vicat Needle EN 1.13 mm dia. |
UTCM-0455 |
Consistency Plunger 10 mm dia. |
UTCM-0458 |
Transfer Dish for UTCM-0451 |
UTGT-1305 |
Glass Thermometer Max. 110°C |
UTCM-0457 |
Additiniol Weight, 700 gr, EN 480-2 |
Information
EN 196-3, 480-2; ASTM C187, C191; AASHTO T129, T131
The Vicat test equipment is used for determining the setting time and consistency of cement by Vicat Method.
Vicat Apparatus consist of metal frame with a scale, Ø10mm consistency plunger and supporting glass plate.
The needle/s, mould, thermometer and transfer dish (for EN) should be ordered seperately.
UTCM-0453A UTCM-0455 UTCM-0453E UTCM-0454E
Dimensions | 150x190x318 mm |
---|---|
Weight (approx.) | 3 kg |
Manuel Mortar Mixers
Product code
UTCM-0875E |
Manuel Mortar Mixer, EN |
UTCM-0875A |
Manuel Mortar Mixer, ASTM |
UTCM-0876 |
Spare Bowl, 5 L |
UTCM-0878E |
Spare Beater, EN |
UTCM-0878A |
Spare Beater, ASTM |
Information
Models for 220-240 V 50-60 Hz, 1ph. |
UTCM-0875E | UTCM-0875A |
Models for 110-120 V 60Hz, 1ph. |
UTCM-0875E-N | UTCM-0875A-N |
Standards
EN 196-1, 196-3, 413-2, 459-2, 480-1, 1015-2, 12617-4;
ASTM C187, C305, AASHTO T129, T131, T162
The UTCM-0875 Manual Mortar Mixer has a 5 liter (approx.) capacity, they have been designed to mix mortars and cement pastes primarily to the requirements of standards.
The mixing paddles revolve at a rate of 140 rpm. with a planetary motion of 62 rpm. in low speed. In high speed, the paddles revolve at the rate of 285 rpm. with a planetary motion of 125 rpm.
The user can choose the speeds easily by using the switch fitted to the machine. There is a sand filling apparatus on the mixers to pour sand easily. The bowl and beater are easily fitted and removed from mixer.
The Manual Mortar Mixers are supplied complete with;
- Bowl, 5 L (approx.)
- Beater
UTCM-0878E UTCM-0876
Dimensions | 300x555x610 mm |
---|---|
Weight (approx.) | 54 kg |
Power | 200 W |
Automatic Programmable Mortar Mixer
Product code
UTCM-0885E |
Automatic Programmable Mortar Mixer |
UTCM-0885A |
Automatic Programmable Mortar Mixer |
UTCM-0876 |
Spare Bowl, 5 L |
UTCM-0878E |
Spare Beater, EN |
UTCM-0878A |
Spare Beater, ASTM |
Information
Models for 220-240 V 50-60 Hz, 1ph. |
UTCM-0885E | UTCM-0885A |
Models for 110-120 V 60Hz, 1ph. |
UTCM-0885E-N | UTCM-0885A-N |
Standards
EN 196-1, 196-3, 413-2, 459-2, 480-1, 1015-2, 12617-4; ASTM C187, C305; AASHTO T129, T131, T162
The mixers have been designed to mix mortars and cement pastes primarily to the requirements of standards. The mixing paddles have a planetary motion and is driven by a motor with a microprocessor based speed and preset programs to meet all listed EN and ASTM standards, custom designed programs or manual mode. The mode button is used for the fast selection of different programs.
The mixing paddles revolve at a rate of 140 rpm. with a planetary motion of 62 rpm. in low speed. In high speed, the paddles revolve at the rate of 285 rpm. with a planetary motion of 125 rpm. An automatic sand dispenser is supplied with the machine and the sand is automatically discharged. Custom design allows 6 programs to be set by the operator, where the motor speed, sand dispenser position and duration of the mix can be set. For the mix where the motor speed is selected as zero, the bowl can be lowered without interrupting the rest of the program. On the display the user can see the mix time and the machine is equipped with lamp in order to warn the user for critical time periods.
The Automatic Programmable Mortar Mixers are supplied complete with;
- Bowl, 5 lt (approx.)
- Beater
UTCM-0878E UTCM-0876
Dimensions | 300x555x610 mm |
---|---|
Weight (approx.) | 56 kg |
Power | 200 W |
CEN Standard Sand
Product code
UTCM-0880 |
CEN Standard Sand, 1350 gr |
Information
Dimensions | 300x190x70 mm |
---|---|
Weight (approx.) | 1350 gr |
Curing Cabinet
Product code
UTCM-1100 |
Curing Cabinet 1000 L |
Information
EN 196-1; ISO 679
UTCM-1100 Curing Cabinet, 1000 Liters, for cement based mortar specimens, 20.0 ± 1.0°C temperature and over 90% Rh humidity. The humidity and temperature can be controlled and monitored by a digital unit. Stainless steel interior. Supplied with six displaceable shelves and a Utest Software. 220-240V, 50-60Hz, 1ph.
The humidity and temperature can be controlled and monitored on the digital control unit.
UTCM-1100 Curing Cabinet is also supplied complete with six displaceable shelves.
Internal Dimension |
1140x680x1370 mm |
---|---|
External Dimension |
1400x800x2100 mm |
Weight (approx.) |
200 kg |
Power |
1200 W |
Jolting Table
Product code
UTCM-0890 | Jolting Table, EN |
UTCM-0891 | Jolting Table with Soundproof Safety Cabinet, EN |
UTCM-0892.2 | Three Gang Mould for 40x40x160 mm, HV200 |
UTCM-0892.4 | Three Gang Mould for 40x40x160 mm, HV400 |
UTCM-0893 | Feed Hopper for UTCM-0892 |
UTCM-0894 | Short and Long Spreaders and Straightedge, for UTCM-0892 |
Information
Models for 220-240 V 50 Hz, 1ph. |
UTCM-0890-T | UTCM-0891-T |
Models for 220-240 V 60 Hz, 1ph. |
UTCM- 0890-K | UTCM- 0891-K |
Standards
EN 196-1; ISO 679
Jolting Table is used for compacting of cement specimens in 40x40x160 mm mould and consists of mould table seated on a rotating cam driven at 60 r.p.m. The falling height is 15 mm conforming to EN 196-1. The machine is equipped with a counter which provides automatic shut off at end of preset drop numbers.
Weight and dimensions of the jolting table fully comply with the requirements of EN 196-1 standard. When used with UTCM-0892 Three Gang Mould and UTCM-0893 Feed Hopper, the total weight of the moving part is 20 kg ± 0.5 kg. Without UTCM-0892 and UTCM-0893 the weight of the moving parts is 6.85 kg. Rapid mould lock and release system allows easy and quick operation.
The supporting frame of the machine has been designed to ensure precise dimensions, table flatness, correct centering of the three gang mould on the table.
The motor and gearbox assembly is enclosed in a protective housing, which promotes user safety (the moving parts are inaccessible) and long life for the gearbox.
The standard model can be supplied with a safety/noise reduction cabinet. The cabinet is lined internally with soundproofing material to reduce sound level conforming to CE directives.
UTCM-0893 Feed Hopper is used for filling UTCM-0892 Three Gang Moulds placed on the Jolting Table.
UTCM-0892 Three Gang Mould, UTCM-0893 Feed Hopper, UTCM-0894 Short and Long Spreaders and Straightedge should be ordered separately.
UTCM-0890 | UTCM-0891 | |
---|---|---|
Dimensions | 1050x350x500 mm | 1440×500×575 mm |
Weight (approx.) | 55 kg | 125 kg |
Motor Speed | 60 r.p.m | |
Drop Height | 15 mm | |
Power | 250 W |
Three Gang Mould
Product code
UTCM-0892.2 |
Three Gang Mould 40.1x40x160 mm, Steel, EN, Minimum Hardness HV200. |
UTCM-0892.4 |
Three Gang Mould 40.1x40x160 mm, Steel, EN, Minimum Hardness HV400. |
UTCM-0893 |
Feed Hopper for UTCM-0892 |
UTCM-0894 |
Short and Long Spreaders and Straightedge for UTCM-0892 |
UTCM-0895 |
Three Gang Cube Mould 50x50x50 mm, Steel, ASTM |
UTCM-0898 |
Three Gang Cube Mould, 2” Plastic |
UTCM-0899A |
Three Gang Mould 40x40x160 mm, Steel, ASTM |
UTCM-0926 |
Cube Mould 70.7 mm, Steel, for UTCM-0930, BS |
Information
Dimensions | Weight (approx.) | |
---|---|---|
UTCM-0892 | 300x190x70 mm | 12 kg (Packed) |
UTCM-0893 | 210x200x40 mm | 2 kg (Packed) |
UTCM-0895 | 110x230x60 mm | 3 kg |
UTCM-0898 | 110x250x70 mm | 1 kg |
UTCM-0899A | 300x190x70 mm | 12 kg (Packed) |
UTCM-0926 | 100x125x90 mm | 3,5 kg |
Vibrating Machine
Product code
UTCM-0930 |
Vibrating Machine for 70.7 mm Cube Moulds, BS |
UTCM-0926 | Cube Mould 70.7 mm, BS |
Information
Models for 220-240 V 50 Hz, 1ph. | UTCM-0930-T |
Models for 220-240V 60 Hz, 1 ph. | UTCM-0930-K |
Standards
BS 4550
The UTCM-0930 Vibrating Machine is used for the preparation and compaction of 70.7 mm mortar cube specimens. The mould table is mounted on four springs attached to an eccentric shaft which allows each sample to be vibrated at 12000 cycles per minute. There is a timer on it to preset time and it stops automatically in every 120 seconds.
70.7 mm cube mould (UTCM-0926) should be ordered separately.
UTCM-0926
Dimensions | 450x650x850 mm |
---|---|
Weight (approx.) | 80 kg |
Eccentric Shaft Rotation | 12000 r.p.m |
Power | 1100 W |
Distance Pieces and Platens for Frames for Cement & Mortar
Product code
UTC-4630 |
Distance Piece Ø165mm x 15mm (Ø6,5”x0,59”) |
UTC-4631 |
Distance Piece Ø165mm x 30mm (Ø6,5”x1,18”) |
UTC-4633 |
Distance Piece Ø165mm x 50mm (Ø6,5”x1,97”) |
UTC-4634 |
Distance Piece Ø165mm x 100mm (Ø6,5”x3,93”) |
UTCM-4116 |
Lower and Upper Loading Platen with Ball Seating Assembly |
Information
Distance Pieces for Frame
Due to the modular design of the frames any sample with suitable size, load and pace rate can be test on both chambers by decreasing the distance between platens.
Loading Platens
UTCM-4116 Lower and Upper (spherical seated) Loading Platens are manufactured from high quality steel smoothed and finished.
The roughness value for the surface texture of machine and auxiliary platens are 3.2 μm.
Air Entrainment Meter for Mortar
Product code
UTCM-0666 |
Air Entrainment Meter for Mortar 1 lt. |
UTCM-0662E |
Tamper EN Ø 40×200 mm 250 gr |
Information
EN 413-2, 459-2, 1015-7
The UTCM-0666 Air Entrainment Meter for Mortar is used for determining the air content of cement paste, cement mortar and lime mortar.
The air entrainment meter is manufactured from cast aluminum, the upper part and the lower test pot are held together with an air-tight seal which are easily adjusted by using the two spring clamps.
The pressure gauge is installed in the head of the meter and the scale works in the 0-20 volumetric % range. The air is compressed with a hand pump installed in the system and the smart configuration of the test and correction buttons enables fast and simple testing.
Dimensions |
200x200x320 mm |
---|---|
Weight (approx.) |
3,5 kg |
Flow Cone Apparatus
Product code
UTCM-0700E |
Flow Cone Apparatus |
UTCM-0701E |
Flow Cone |
UTCM-0702E |
Ø:8 mm Nozzle |
UTCM-0703E |
Ø:9 mm Nozzle |
UTCM-0704E |
Ø:10 mm Nozzle |
UTCM-0705E |
Ø:11 mm Nozzle |
UTCM-0706E |
Ø:13 mm Nozzle |
Information
EN 445
UTCM-0700E Flow Cone Apparatus is used for determining the flow properties of grouts, mortars, muds and other fluid materials.
The Flow Cone Appratus is supplied complete with;
- Cone, Sieve 1,5 mm
- Cup 1 lt
- Nozzle 10 mm
- Fitting Bush
- Stand
Ø:8, 9, 10, 11, 13 mm Nozzle
Dimensions | 250x250x600 mm |
---|---|
Weight (approx.) | 10 kg |
Marsh Funnel Viscometer
Product code
UTCM-0750 |
Marsh Funnel Viscometer |
Information
ASTM D6910, API Recommended Practice 13B-1
The UTCM-0750 Marsh Funnel Viscometer is used for the determination of flow time by the use of flow cups of fluid materials such as paint, varnish etc. Manufactured from breakresistant rugged plastic to avoid deformations on temperature changes so the volumetric accuracy is maintained. Accurate measurements are taken using the metal orifice.
To avoid the operator’s hands coming into contact with the test material, a handle is provided. Supplied complete with 1 liter capacity plastic measuring cup.
Top Diameter |
150 mm |
---|---|
Nozzle Length |
50 mm |
Internal Diameter |
5 mm |
Total Length |
355 mm |
Weight (approx.) |
0,5 kg |